Power Test System
MI-TS-3871
Multi-channel system for energy-saving tests and simulations
The MI-TS system is more than just a battery tester. It is a comprehensive testing powerhouse designed to handle a wide range of tasks. Need to analyze battery performance through charging, discharging, and simulation? The MI-TS has you covered. It can also efficiently load fuel cells and evaluate critical components like contactors, fuses, and DC motors used in drive trains. But the MI-TS does not stop there. Its versatility extends to testing charging columns and even providing power for train maintenance, making it an invaluable tool for diverse testing needs.
Safety is paramount with the MI-TS. This system adheres to stringent PLd safety standards and incorporates features like emergency stops and isolated outputs to prioritize user and equipment protection. Control is also a breeze thanks to its versatile interface options like Modbus TCP/IP, CAN-Bus, and SCPI. Additionally, optional compatibility with Profibus, Profinet, and LabView allows for a truly customized testing experience. With exceptional power delivery, short-circuit protection, and precise control, the MI-TS delivers top-notch performance for reliable results.
Benefits of Power Test System MI-TS-3871
Multi-channel system for energy-saving tests and simulations. Two or four outputs, up to 1200 V and 1200 A per output (without galvanic isolation between the DC outputs).
Technical data Power Test System MI-TS-3871
Technical specifications | |
AC - Input Voltage / AC – Input Frequency | 480 V ± 10 %, 3-phase, PE, 60 Hz ± 5 % *Other voltages available upon request |
Measuring resolution | Voltage: 16 Bit ADC Current: 16 Bit ADC |
Control accuracy | Voltage 0.05 % fs Current 0.05 % fs |
Voltage tolerance dynamic (0 – 100 % INom in 3 ms) | < 3 % fs |
Voltage ripple | ≤ 0.1 % eff. fs |
Current ripple | ≤ 0.1 % eff. fs |
Short circuit behavior | Short circuit proof (Icw < 3 kA) |
Permissible ambient temperature | +5 to +40 °C |
Climate class | 1K21/1M11 according to EN60721 (85 % relative humidity non condensing with cabinet heating up to 95 % relative humidity without condensing) |
Distance from ceiling min. | 300 (standard, IP20) |
Installation | Operating area with restricted access installation on non-flammable floor |
Protection class | IP20 according to IEC 60529, others on request |
Safety | EN ISO 13849-1 |
Basic standard | EN 62040 |
EMC | EN 61000-2-4 grid disturbances EN 61000-6-2 interference immunity EN 61000-6-4 interference emission EN 61800-3 Kat C2 (A1) variable – speed electrical drives |
Downloads
Contact us
If you have questions or want to know more about Power Test Systems, please fill in the contact form below. We will get back to you as soon as possible.
More solutions